Based on system estimation, a method for measuring Jones-Mueller matrices of optical fiber systems using optical fiber wave-plates is proposed, and studied theoretically and experimentally. The measurement system uses optical fiber wave-plates that match the fiber system naturally. The method is feasible but with drawbacks of environmental sensitivity. To overcome the problem, a method for calibrating the retardance of waveplates is proposed and realized based on the property of similar matrices. Adjustment of rotation of optical fiber wave-plate is also achieved using system optimization. Both retardance calibration and rotation adjustment are verified experimentally. Significant improvement in the reduction of system error has been shown. The spectra of Mueller matrices of two segments of fiber in tandem are measured in the region of 1 520~1 620 nm using the proposed method.
LEI Jun-ping, WANG Chun-hua, YU Qing-yang, DU Yan-xia, ZHANG Bin
. Measurement of Jones-Mueller matrix for cascaded optical system[J]. Journal of Shanghai University, 2015
, 21(5)
: 525
-535
.
DOI: 10.3969/j.issn.1007-2861.2014.05.014
[1] Guo X X, Wood M F, Vitkin A I. Angular measurements of light scattered by turbid chairal media using linear Stokes polarimeter [J]. Journal of Biomedical Optics, 2006, 11(4): 041105.
[2] Wallenburg M A, Wood M F, Ghosh N. Polarimetry-based method to extract geometry independent metrics of tissue anisotropy [J]. Optics Letters, 2010, 35(15): 2570-2572.
[3] 黄凯, 王志亮, 周哲玮, 等. 蒸发微粒气体对光的消光特性[J]. 上海大学学报: 自然科学版, 2013, 19(6): 599-605.
[4] Takechi H, Arteaga O, Ribo J M, et al. Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methods [J]. Optics Letters, 2011, 16(5): 3636-3647.
[5] Azzam R M A. Photopolarimetric measurement of the Mueller matrix by Fourier analysis of a single detected signal [J]. Optics Letters, 1977, 2(6): 148-150.
[6] Jellision G E, Modine F A. Two-modulator generalized ellipsometry: experiment and calibriation [J]. Applied Optics, 1997, 36(31): 8184-8189.
[7] Matino A D, Kim Y K, Garcia-Caurel E, et al. Optimized Mueller polarimeter with liquid crystals [J]. Optics Letters, 2003, 28(8): 616-618.
[8] Otani Y, Chujo M. Spectroscopic Mueller matrix polarimeter by double liquid crystal phase modulators [C]//Proc SPIE. 2009: 74610Q.
[9] 曹绍谦, 步扬, 王向朝, 等. 基于单光弹调制器的米勒矩阵测量方法[J]. 光学学报, 2012, 33(1): 0112006.
[10] Lin J F, Chang C C, Syu C D, et al. A new electro-optic modulated circular heterodyne interferometer for measuring the rotation angle in a chiral medium [J]. Optics and Laser in Engineering, 2009, 47(1): 39-44.
[11] Zeng A J, Li F Y, Zhu L L, et al. Simultaneous measurement of retardance and fast axis angle of a quarter-wave plate using one photoelastic modulator [J]. Applied Optics, 2011, 50(22):
4347-4352.
[12] Tripathi S, Toussaint K C. Rapid Mueller matrix polarimetry based on parallelized polarization state generation and detection [J]. Optics Express, 2009, 17(24): 21396-21407.
[13] Dong K H, Shum P, Yan M, et al. Measurement of Mueller matrix for an optical fiber system with birefringence and polarization-dependent loss or gain [J]. Optics Communications, 2007,
274(1): 116-123.
[14] Dong H, Gong Y D, Paulose V, et al. Optimum input states of polarization for Mueller matrix measurement in a system having finite polarization-dependent loss or gain [J]. Optics Express,
2009, 17(25): 23044-23057.
[15] 贾恺, 姚寿铨. 光纤A/4波片的温度特性[J]. 上海大学学报: 自然科学版, 2009, 15(5): 457-460.
[16] Lu S Y, Chipman R A. Interpretation of matrices based on polar decomposition [J]. Journal of Optic Science, 1996, 13(5): 1106-1113.
[17] Barakat R. Bilinear constrains between elements of the 4×4 Mueller-Jones transfer matrix of polarization theory [J]. Optics Communications, 1981, 38(3): 159-161.
[18] Ibarra-Escamilla B, Kuzin E A, Pottiez O, et al. Fiber optical loop mirror with a symmetrical coupler and a quarter-wave retarder plate in the loop [J]. Optics Communications, 2004, 242(1/2/3): 191-197.