In the simulation of flue gas, free ammonia at the export of spray tower was used as the monitoring object. Factors of influence including pH value and concentration of absorption liquid, volume ratio of liquid to gas (L/G) and inlet gas temperature on the efficiency of flue gas desulphurization (FGD) were studied. Experimental results show that the amount of ammonia escape increases as the pH value, concentration of absorption liquid and L/G increase. To control ammonia escape and the high rate of desulphurization, appropriate parameters should be used, including pH value of 6.0, concentration of absorption ((NH4)2SO3) of 1%, L/G of 4 L/m3, and inlet gas temperature of 90~110 ℃.
SONG Gui-dong, WAN Hao, SHAO Shen, CHAN Wen-bing, GU Xiao-jing
. Ammonia Escape in Flue Gas Desulphurization by Ammonia Method[J]. Journal of Shanghai University, 2013
, 19(6)
: 615
-618
.
DOI: 10.3969/j.issn.1007-2861.2013.06.012
[1] 李卫清. CeO2 对CuO/γ-Al2O3 分散及烟气脱硫性能的影响[J]. 上海大学学报: 自然科学版, 2010, 16(3): 298-300.
[2] 蔡震峰. 氨法烟气脱硫技术综述[J]. 现代化工, 2012, 32(8): 9-10.
[3] 杜冬冬. 氨-硫酸铵法烟气脱硫工艺研究[D]. 南京: 南京理工大学, 2009.
[4] Jia Y, Zhong Q, Fan X Y, et al. Kinetics of oxidation of total sulfite in the ammonia-based wet flue gas desulfurization process [J]. Chemical Engineering Journal, 2010, 164: 132-138.
[5] 崔建祥, 赵焰. 氨法脱硫副产物亚硫酸铵的塔外氧化[J]. 电力环境保护, 2009, 25(3): 21-22.
[6] 张三虎, 包俊江. 湿法烟气脱硫系统中影响脱硫效率的关键参数[J]. 环境工程, 2009, 27(2): 22-24.
[7] Zhong Y, Gao X, Luo Z Y, et al. Factors influencing desulfurization efficiency of wet flue gas desulfurization system [J]. Journal of Zhejiang University: Engineering Science, 2008, 42(5): 890-894.
[8] 胡伟锋. 大型电站锅炉煤种适应性探讨[J]. 电力设备, 2004, 5(11): 61-63.
[9] 王春昌. 入炉风量与炉膛出口烟气温度的相关性研究[J]. 热力发电, 2007, 7: 37-39.
[10] 邵申. 氨法烟气脱硫技术的工艺研究[J]. 环境工程, 2011, 29(5): 72-74.