Civil Engineering

Analysis of progressive collapse resistance of bolted beam-to-upright connection substructures in steel storage racks

  • DAI Liusi ,
  • YAO Hao ,
  • REN Chong
Expand
  • School of Mechanics and Engineering Science, Shanghai University, Shanghai 200444, China

Received date: 2024-05-27

  Online published: 2026-07-04

Abstract

To study the progressive collapse resistance of bolted beam-to-upright connections in steel storage racks, an experimental study was conducted on their double half-span substructures under a middle column removal scenario to explore the effects of no-load and half-load conditions on the internal force effects and resistance performance of the substructures. The full-range load-displacement curves and typical failure modes of the substructure specimens were provided, and it was found that the typical failure mode of the bolted beam-to-upright connections was the combination of tab crack and bolt bearing failure leading to tearing of beam-end-connector (T+B). A full-scale refined finite element model was constructed, and its reliability was validated by comparing with the experimental results. Furthermore, the effects of the number and positions of bolts on the progressive collapse resistance of the substructures were explored. The experimental results showed that compared with the beam-to-upright connection substructure specimen locked with one upper bolt under no-load, the pallet cargo load weakened the ultimate vertical resistance and deformation capacity of the bolted beam-to-upright connection substructures. Locking two bolts (upper and lower) significantly improved the ultimate vertical resistance of the substructures, but the ultimate deformation capacity was poor. Locking one lower bolt slightly improved the ultimate vertical resistance of the connection substructures, while the ultimate deformation capacity of the substructures significantly decreased. For the progressive collapse resistance design of beam-to-upright connections in steel storage racks, it was recommended to lock one upper bolt or two bolts (upper and lower) to improve the structural robustness against progressive collapse.

Cite this article

DAI Liusi , YAO Hao , REN Chong . Analysis of progressive collapse resistance of bolted beam-to-upright connection substructures in steel storage racks[J]. Journal of Shanghai University, 2026 , 32(3) : 447 -463 . DOI: 10.12066/j.issn.1007-2861.2589

References

[1] 李晓东, 李永录. 钢货架结构倒塌实例分析[J]. 钢结构, 2012, 27(7): 49-51.
[2] McConnel R E, Kelly S J. Structural aspects of the progressive collapse of warehouse racking [J]. Structural Engineer, 1983, 61: 343-347.
[3] Kelly S J. Structural aspects of the progressive collapse of warehouse racking [D]. Cambridge: University of Cambridge, 1982.
[4] Bajoria K M. Three dimensional progressive collapse of warehouse racking [D]. Cambridge: University of Cambridge, 1986.
[5] Ng A L Y, Beale R G, Godley M H R. Methods of restraining progressive collapse in rack structures [J]. Engineering Structures, 2009, 31(7): 1460-1468.
[6] Gilbert B. P. The behaviour of steel drive-in racks under static and forklift truck impact forces [D]. Sydney: The University of Sydney, 2010.
[7] Gilbert B P, Rasmussen K J R. Determination of accidental forklift truck impact forces on drive-in steel rack structures [J]. Engineering Structures, 2011, 33(5): 1403-1409.
[8] Gilbert B P, Rasmussen K J R. Impact tests and parametric impact studies on drive-in steel storage racks [J]. Engineering Structures, 2011, 33(5): 1410-1422.
[9] Zhang H, Gilbert B P, Rasmussen K J R. Drive-in steel storage racks. II: reliability-based design for forklift truck impact [J]. Journal of Structural Engineering, 2012, 138(2): 148-156.
[10] 熊强. 叉车冲击作用下钢货架抗连续倒塌性能研究[D]. 南京: 东南大学, 2018.
[11] Affolter C, Piskoty G, Wullschleger L, et al. Collapse of a high storage rack [J]. Engineering Failure Analysis, 2008, 16(6): 1846-1855.
[12] Vayas I, Avgerinou S, Thanopoulos P. Failure of a steel pallet rack in Athens [J]. Der Stahlbau, 2018(1): 30-37.
[13] Dubina D, Marginean I, Dinu F. Impact modelling for progressive collapse assessment of selective rack systems [J]. Thin-Walled Structures, 2019, 143: 106201.
[14] 任重, 刘家巍, 戴柳丝. 冷弯薄壁型钢货架梁柱节点子结构抗连续性倒塌性能研究[J]. 建筑钢结构进展, 2022, 24(9): 36-44, 66.
[15] Li L, Wang W, Chen Y, et al. Effect of beam web bolt arrangement on catenary behavior of moment connections [J]. Journal of Constructional Steel Research, 2015, 104: 22-36.
[16] Li L, Wang W, Chen Y, et al. Experimental investigation of beam-to-tubular column moment connections under column removal scenario [J]. Journal of Constructional Steel Research, 2013, 88: 244-255.
[17] Yan S, Rasmussen K J R, Liu X, et al. Behaviour of H-section purlin connections in resisting progressive collapse of roofs [J]. Engineering Structures, 2019, 201: 109849.
Outlines

/