多晶碘化汞膜正逐渐成为制备室温下X射线成像探测器的优异半导体材料. 设计8组不同栅宽和沟宽的共面栅探测器电极结构, 进而使用有限元软件ANSYS对其进行模拟分析,得到相应的电势分布. 结果发现, 结构E(栅宽为150 μm, 沟宽为500 μm)的电极设计效果最佳. 之后, 进一步设计了2组电极结构, 用以研究在不对称电极形状所导致的边缘效应影响下的电势分布, 结果发现通过加宽边缘第二个栅极(结构N)可以实现优化共面栅电极设计的目的, 从而降低边缘效应产生的影响.
Polycrystalline mercuric iodide films are developed as new detectors in room temperature X-ray imaging. In this paper, 8 different electrode patterns are designed by varying the widths of grid and gap. Finite element analysis is used to simulate the potential distribution of the coplanar-grid detectors. The electrode design of pattern E, with width of grid 150 μm and width of gap 500 μm, is the best. The influence of edge effects resulting from the unsymmetrical electrodes on the potential distribution is discussed. The geometry of electrodes for coplanar-grid detectors is optimized by widening the second grids near edges as shown in pattern N.
[1] Van Den Berg L, Pauly S W. Recent advances in mercuric iodide detector fabrication and instrument development [C]//Proc SPIE. 1999: 206-210.
[2] Schieber M, Hermon H, Zuck A, et al. Thick films of X-ray polycrystalline mercuric iodide detectors [J]. J Cryst Growth, 2001, 225(2): 118-123.
[3] Shih C T, Huang T J, Luo Y Z, et al. Oriented polycrystalline α-HgI2 thick films grown by physical vapor deposition [J]. J Cryst Growth, 2005, 280(3): 442-447.
[4] Ahmed G, Dashora A, Sharma M, et al. Compton profiles and electronic structure of HgBr2 and HgI2 [J]. Appl Radiat Isot, 2010, 68(2): 286-292.
[5] Alexive D, Dytlewski N, Reinhard M I, et al. Characterization of single-crystal mercuric iodide [J]. Nucl Instrum Methods Phys Res A, 2004, 517(1): 226-229.
[6] Iwanczyk J S. Advances in mercuric iodide X-ray detectors and low noise preamplification systems [J]. Nucl Instrum Methods Phys Res A, 1989, 283(2): 208-214.
[7] 葛艳辉, 郭余英, 史伟民, 等. In的掺杂对化学水浴沉积SnS薄膜电阻率的影响[J]. 上海大学学报: 自然科学版, 2007, 11(4): 407-410.
[8] Schieber M, Hermon H, Zuck A, et al. Theoretical and experimental sensitivity to X-rays of single and polycrystalline HgI2 compared with different single-crystal detectors [J]. Nucl Instrum
Methods Phys Res A, 2001, 458(1): 41-46.
[9] Iwanczyk J S, Patt B E, Tull C R, et al. Mercuric iodide polycrystalline films [C]//Proc SPIE. 2001: 28-40.
[10] Pan M J, Shi W M, Lei P S, et al. Growth and characterization of polycrystalline mercuric iodide thick films [J]. J Synth Cryst, 2004, 33(1): 109-113.
[11] 王东, 闵嘉华, 梁小燕, 等. 溶液法制备CdZnTe晶体中Te夹杂相分析[J]. 上海大学学报: 自然科学版, 2013, 19(1): 67-70.